Six-order elliptic combline filter with electric probe

Journal article


Authors/Editors


Research Areas

No matching items found.


Publication Details

Author list: Chuma JM, Mirshekar-Syahkal D, Abbas F, Normington P, Zadeh M

Publisher: Wiley

Place: NEW YORK

Publication year: 1999

Journal: Microwave and Optical Technology Letters (0895-2477)

Journal acronym: MICROW OPT TECHN LET

Volume number: 20

Issue number: 5

Start page: 290

End page: 292

Number of pages: 3

ISSN: 0895-2477

eISSN: 1098-2760

Languages: English-Great Britain (EN-GB)


View in Web of Science | View citing articles in Web of Science


Abstract

An electric probe is used between two crossed coupled combline resonators in order to realize the required electric coupling for a six-pole elliptic function filter This realization eliminates the need for resonators with long posts, providing filter. compactness and offering a flexible and wide range of couplings. The measured frequency response of the lifter shows good agreement with the theoretical analysis. (C) 1999 John Wiley & Sons, Inc.