ZnO nanowire-FET for charge-based Sensing of protein biomolecules
Conference proceedings article
Authors/Editors
Research Areas
No matching items found.
Publication Details
Author list: Ditshego NMJ, Ghazali NAB, Ebert M, Sun K, Zeimpekis I, Ashburn P, de Planque MRR, Chong HMH
Publisher: IEEE
Place: NEW YORK
Publication year: 2015
Start page: 801
End page: 804
Number of pages: 4
eISBN: 978-1-4673-8155-0
Languages: English-Great Britain (EN-GB)
View in Web of Science | View citing articles in Web of Science
Abstract
Top-down method was used to zinc oxide (ZnO) nanowire field effect transistor (NWFET) biosensor. The nanosensor was used to measure the electrical characteristics of lysozyme (LYSO) and bovin serum albumin (BSA) protein solutions in phosphate buffered saline (PBS). The LYSO and BSA proteins are oppossitely charged at measurement pH of 7.4. Subthreshold voltage shift of 340 mV and 700 mV due to surface charge effect on the device channel is obtained for the LYSO and BSA solution respectively. A NWFET sensitivity of 72 % is achieved for the LYSO proteins while the BSA proteins resulted in a sensitivity of 98%.
Keywords
bovine serum albumin (BSA), DEVICE, Field effect transistor, lysozyme (LYSO), nanosensor, Nanowire, phosphate buffered saline (PBS), zinc oxide
Documents
No matching items found.